Air Purifier for Room Size: How to Pick the Right CADR

Air Purifier for Room Size: How to Pick the Right CADR

To choose an air purifier for your room size, multiply floor area in sq ft by ceiling height in ft, then by 0.0283 and by the air changes per hour you want. The answer is the CADR in cubic metres per hour. For a 200 sq ft room with an 8 ft ceiling at 5 air changes per hour, that is about 226 m³/h.

Image: a worked CADR calculation. Alt text: "air purifier CADR formula for a 200 square foot room".

The CADR sizing formula

The formula comes from Tech Mitra's buying guide:

CADR (m³/h) = floor area (sq ft) × ceiling height (ft) × 0.0283 × ACH

ACH is the number of times the purifier should clean the whole room's air each hour. Guides for polluted cities suggest 5 to 6 ACH rather than 4.

CADR needed by room size

The table assumes an 8 ft ceiling and is calculated with the formula above.

Room size (sq ft)

CADR at 5 ACH (m³/h)

CADR at 6 ACH (m³/h)

100113136
150170204
200226272
300340408
400453543

Higher ceilings raise the number, so recalculate if your room is taller than 8 ft. To compare the CADR figure with a brand's coverage claim, read CADR vs room coverage.

Other rules of thumb give different answers

Sizing advice is not uniform. Some guides say CADR should be about 1.5 times the room area in sq ft, while the AHAM rule is 0.67 cfm per sq ft and other guides use 0.13 to 0.14 sq m per CADR unit. Because those methods differ, use one formula consistently and check it against the manufacturer's figure.

Room size and local air in three cities

Room type changes the target

Bedrooms need low noise as well as CADR, while shared living rooms need a higher figure for open layouts. For the trade-offs, read air purifier for bedroom vs living room. For a better grade of filtration, see HEPA H13 vs H14.

Frequently asked questions

What CADR do I need for a 200 sq ft room?

About 226 m³/h at 5 ACH and 8 ft ceilings, or about 272 m³/h at 6 ACH.

Is a bigger purifier always better?

Not always. A larger unit costs more and may be louder, but it can run on a lower, quieter setting.

Does ceiling height matter?

Yes. The formula multiplies by ceiling height, so a 10 ft ceiling needs a higher CADR than 8 ft.

Can one purifier cover two rooms?

Usually not. Use one purifier per room, particularly when doors stay closed.

Conclusion

Measure the floor, note the ceiling, choose 5 or 6 ACH and read the result as your minimum CADR. The next question is which number on the box to trust, so compare CADR with room coverage claims.